ASTM C744 specifies the following tests for pre-faced glazed
concrete masonry units
|
| Cracking and Crazing |
A test to ensure that the units are free from cracking and/or
crazing. |
Complies |
| Resistance to Staining and Chemicals |
Testing of various chemicals, i.e., detergents, solvents,
etc., in concentrations set by ASTM standards and ASTM requirements. |
Complies |
| Adhesion |
A test to determine the adhesion of the glazed facing to the
block substrate. |
Complies |
| Abrasion |
A test to measure the abrasion resistance of the glazed facing. |
Complies |
| Color Change |
A test by accelerated weathering apparatus to measure color
fading or change. |
Complies |
| Soiling and Cleansability |
A test to determine how easily the glazed surface can be cleaned. |
Complies |
| Efflorescence |
A test to ensure that unsightly soluble salts do not migrate
to the surface when moisture is present. |
Complies |
| Dimensional Tolerances |
A test to ensure that variations in the sizes of the blocks
in all dimensions are less than 1/16". |
Complies |
| Efflorescence |
A test to ensure that unsightly soluble salts do not migrate
to the surface when moisture is present. |
Complies |
| Dimensional Tolerances |
A test to ensure that variations in the sizes of the blocks
in all dimensions are less than 1/16". |
Complies |
| Face Variation |
A test to ensure that the glazed facing dimensions do not
vary more than 1/16". |
Complies |
| Depth Variation |
A test by measurements to ensure that the thickness of the
prefaced block are within 1/16" of the specified size. |
Complies |
| Distortion of Facing |
A test by measurements to ensure that the glazed facing is
straight, true and in plane within 1/16". |
Complies |
| Surface |
A laboratory inspection for quality of the face (no imperfection). |
Complies |
| Flame Spread Index * |
A test to determine how much the glazed facing will allow
flame to spread in a fire. |
Complies |
| Smoke Development ** |
A test to determine the amount of smoke given off by the glazed
facing in a fire. |
Complies |
* The test method specified in ASTM E84 is
used to determine surface burning characteristics.
** In this test, red oak is given a value of 100 and asbestos
cement board is given a value of 0 to calibrate the test equipment. |
|
ASTM C90 specifies the following test for load-bearing concrete
masonry units
|
Compressive Strength and Moisture Absorbency
|
A test to ensure that blocks meet strength and moisture requirements
and are free of cracks and other defects. |
Complies |
|
Canadian Standard CSA-CAN3-A165.3-M85
|
| Aging and Thermal Shock |
A test to ensure that no cracking, spalling, crazing or blistering
of the glaze occurs when the unit is subject to cycles of thermal
shock at 0º and 93º C. |
Complies |
| Other Tests: |
| Freeze/Thaw |
Test A test to ensure that the glazed facing does not crack
or craze when exposed repeatedly to freeze thaw cycles. |
Complies |
| Acid Rain Test |
A test to ensure that acid rain does not mar the face of Astra-Glaze-SW+
blocks. |
Complies |
| Diesel Fume Exhaust |
Test A test to measure the effect of prolonged diesel fume
exhaust on the facing of Astra-Glaze-SW+ blocks. |
Complies |
| Waste Water Treatment Plant Test . |
A test to ensure that the glazed facing is not affected by
chemicals found in waste water treatment plant environments |
Complies |
|
ASTRA-GLAZE-SW+ units meet USDA approval
|
| |
|
Industry-Specific Testing
|
Industry-specific certificate of analysis
testing has been completed for ASTRA-GLAZE-SW+ glazed masonry
units by Froehling and Robertson, Inc. Laboratories. ASTRA-GLAZE-SW+
units successfully pass chemical and medical agents, steam,
fuel and detergent testing in:
- Veterinary Hospitals & Clinics
- Animal Shelters
- Power Plants
- Machine Shops
- Heating Plants
- Control Labs
|
- Brewing & Distilling Industries
- Wash Rooms & Showers
- Laundry Rooms
- Dairy Industry
- Jails
|
- Meat Packagers
- Slaughter Houses
- Seafood Industries
- Kitchens & Food Preparation Facilities
- Dish Washing Bars
|
|